故障:TRANSTHERM 酒櫃唔製冷、溫度降不下來
Fault: Wine cooler not cooling, temperature cannot drop
+
原因分析
Cause
壓縮機故障、雪種洩漏、散熱塵垢過多
Compressor failure, refrigerant leak, dirty heat‑dissipation grille
用戶自檢
User Self‑Check
檢查背後散熱位是否被雜物阻擋,門有冇關實
Check rear ventilation blocked, confirm door fully closed
處理方案
Solution
清潔散熱網;雪種測漏加註;損壞需更換壓縮機
Clean grille; leak test & refill refrigerant; replace faulty compressor
維修更換零件
Replacement Parts
壓縮機、雪種、散熱網
Compressor, refrigerant, cooling grille
故障:酒櫃時凍時唔凍,溫度反覆飄移
Fault: Intermittent cooling, unstable temperature fluctuation
+
原因分析
Cause
溫度感應器老化、風扇循環異常、門封漏冷
Aged temperature sensor, circulation fan fault, door seal cold leakage
用戶自檢
User Self‑Check
觀察門膠條是否有縫隙,內籠風扇有無轉動
Check door gasket gap, observe inner fan rotation
處理方案
Solution
更換溫度感應器;維修循環風扇;替換老化門封膠條
Replace sensor; repair circulation fan; renew door gasket
維修更換零件
Replacement Parts
溫度感應器、循環風扇、門封膠條
Temperature sensor, circulation fan, door gasket
故障:TRANSTHERM酒櫃開機完全唔著機,毫無反應
Fault: Wine cooler no power, no response after power‑on
+
原因分析
Cause
電源板故障、保險絲燒毀、電路接線鬆脫
Power board fault, blown fuse, loose wiring
用戶自檢
User Self‑Check
插座測試有冇電,電源插頭是否插穩
Test wall socket, check power plug firmly inserted
處理方案
Solution
檢查更換保險絲;維修電源主板;重接鬆脫線路
Check‑replace fuse; repair power mainboard; reconnect loose wiring
維修更換零件
Replacement Parts
保險絲、電源主板、接線端子
Fuse, power mainboard, wiring terminals
故障:顯示屏黑屏、完全唔亮,但機器仍運轉
Fault: Display black out, unit still running
+
原因分析
Cause
顯示面板故障、接觸線鬆動、主板供電異常
Display panel failure, loose ribbon cable, mainboard power supply abnormal
用戶自檢
User Self‑Check
重新斷電重啟 5 分鐘再開機測試
Power off for 5 minutes then restart
處理方案
Solution
重新插接排線;維修或更換觸控顯示面板
Re‑plug ribbon cable; repair or replace touch‑display panel
維修更換零件
Replacement Parts
觸控顯示面板、排線
Touch display panel, ribbon cable
故障:觸控面板按鍵無反應,無法調校溫度
Fault: Touch panel no response, cannot adjust temperature
+
原因分析
Cause
觸摸面板受潮老化、主板控制模組損壞
Humid‑aged touch panel, damaged mainboard control module
用戶自檢
User Self‑Check
抹乾面板表面水氣,斷電重啟測試
Wipe panel moisture, power‑cycle test
處理方案
Solution
清潔檢查排線;必要更換整套觸控面板
Clean & inspect ribbon cable; replace full touch panel if needed
維修更換零件
Replacement Parts
整套觸控面板、排線
Complete touch panel, ribbon cable
故障:酒櫃不斷發出嗶嗶報警聲
Fault: Continuous beep alarm sound
+
原因分析
Cause
門未關妥、溫度超標、故障代碼觸發警報
Door not fully closed, temperature over‑range, error‑code trigger alarm
用戶自檢
User Self‑Check
關緊櫃門,查看屏幕有冇彈出錯誤代碼
Close door tight, check screen for error code
處理方案
Solution
排除門關閉問題;讀取故障代碼維修對應零件
Fix door‑closing issue; read error‑code & repair corresponding components
維修更換零件
Replacement Parts
門封膠條、感應器、主板
Door gasket, sensor, mainboard
故障:雙溫區酒櫃一邊凍、另一邊唔凍
Fault: Dual‑zone wine cooler one side cold, other side no cooling
+
原因分析
Cause
分區風扇損壞、擋風隔板移位、控溫感應器故障
Zone fan damaged, baffle offset, temperature sensor fault
用戶自檢
User Self‑Check
檢查內籠擋板有冇被酒瓶擋住出風口
Check air outlet blocked by wine bottles & baffles
處理方案
Solution
維修分區循環風扇;更換對應溫度感應器
Repair zone circulation fan; replace matching temperature sensor
維修更換零件
Replacement Parts
分區風扇、溫度感應器
Zone fan, temperature sensor
故障:TRANSTHERM 酒櫃內部結冰、蒸發器結厚霜
Fault: Inner icing, evaporator heavy frost build‑up
+
原因分析
Cause
除霜系統失效、門封漏氣、濕度過高
Defrost system failure, door gasket air leakage, over‑high humidity
用戶自檢
User Self‑Check
停機解凍,檢查門膠條有冇漏冷氣
Power‑off defrost, check gasket cold‑air leakage
處理方案
Solution
維修除霜感應器;更換門封膠圈
Repair defrost sensor; replace door gasket
維修更換零件
Replacement Parts
除霜感應器、門封膠圈
Defrost sensor, door gasket
故障:酒櫃底部滴水、機內漏水積水
Fault: Bottom dripping, inner water pooling / leakage
+
原因分析
Cause
排水孔堵塞、排水管脫落、凝水盤滿溢
Drain hole blocked, drain pipe fallen off, condensate tray overflow
用戶自檢
User Self‑Check
查看底部接水盤是否水滿,清理排水孔異物
Check bottom water tray full, clear drain hole debris
處理方案
Solution
疏通排水管路;重新安裝脫落排水管
Unclog drain pipeline; reinstall fallen‑off drain tube
維修更換零件
Replacement Parts
排水管、接水盤
Drain pipe, condensate tray
故障:運行噪音大、機身震動,嘈吵擾人
Fault: Loud operating noise, heavy cabinet vibration
+
原因分析
Cause
壓縮機腳膠老化、風扇葉片碰殼、零件鬆動
Aged compressor rubber feet, fan blade collision, loose components
用戶自檢
User Self‑Check
檢查酒櫃是否擺放水平,背後有冇牆面碰撞
Check unit level placement, cabinet rear wall collision
處理方案
Solution
更換減震膠腳;維修更換故障風扇馬達
Replace anti‑vibration rubber feet; repair / replace faulty fan motor
維修更換零件
Replacement Parts
減震膠腳、風扇馬達
Anti‑vibration rubber feet, fan motor
故障:櫃門關不緊,容易彈開
Fault: Cabinet door cannot close tight, pops open easily
+
原因分析
Cause
門鉸磨損、門封膠條變形老化
Worn door hinge, deformed & aged door gasket
用戶自檢
User Self‑Check
用紙張夾在門縫測試,紙可輕易抽出即漏冷
Paper slip test: paper easily pulled out = cold‑air leakage
處理方案
Solution
調校門鉸;更換全新門封膠條
Adjust door hinge; install brand‑new door gasket
維修更換零件
Replacement Parts
門鉸、門封膠條
Door hinge, door gasket
故障:酒櫃外殼發熱嚴重
Fault: Wine cooler outer cabinet over‑heating
+
原因分析
Cause
散熱位被封死、環境溫度太高、連續長時間運轉
Ventilation blocked, high ambient temperature, long continuous running
用戶自檢
User Self‑Check
確保機身四周預留 10cm 以上散熱空間
Reserve ≥10cm clearance around unit for ventilation
處理方案
Solution
清理散熱網塵埃;改善周邊通風環境
Clean cooling grille dust; improve surrounding ventilation
維修更換零件
Replacement Parts
散熱網(清潔為主)
Cooling grille (cleaning priority)
故障:櫃內燈光不亮,其他功能正常
Fault: Inner light not working, other functions normal
+
原因分析
Cause
LED 燈條燒壞、燈具接線鬆脫
Burnt‑out LED strip, loose lamp wiring
用戶自檢
User Self‑Check
斷電後輕搖燈帶位置,重啟測試
Power‑off, gently wiggle lamp strip then restart test
處理方案
Solution
重新接駁線路;更換 LED 照明燈條
Reconnect wiring; replace LED light strip
維修更換零件
Replacement Parts
LED燈條、燈具接線
LED light strip, lamp wiring
故障:機器跳掣,開機不久就斷電跳總掣
Fault: Circuit breaker trips shortly after startup
+
原因分析
Cause
壓縮機短路、電容損壞、電路受潮短路
Compressor short‑circuit, damaged capacitor, moisture‑caused short‑circuit
用戶自檢
User Self‑Check
不要反覆重啟,避免擴大故障
Do NOT repeatedly restart to prevent further damage
處理方案
Solution
檢測壓縮機與啟動電容,更換損壞零件
Test compressor & starting capacitor; replace broken components
維修更換零件
Replacement Parts
壓縮機、啟動電容
Compressor, starting capacitor
故障:溫度顯示數字亂跳,讀數不準確
Fault: Temperature display flickering & inaccurate reading
+
原因分析
Cause
溫度探頭損壞、主板訊號異常
Broken temperature probe, abnormal mainboard signal
用戶自檢
User Self‑Check
斷電重啟,觀察是否持續亂數
Power‑cycle & observe if flickering persists
處理方案
Solution
更換溫度感應探頭;檢修主控板
Replace temperature probe; inspect‑repair main control board
維修更換零件
Replacement Parts
溫度探頭、主控板
Temperature probe, main control board
故障:嵌入式TRANSTHERM 酒櫃製冷效果變差
Fault: Built‑in TRANSTHERM wine cooler cooling performance drops
+
原因分析
Cause
櫃體封死散熱空間、通風位被傢俬阻擋
Built‑in cabinet blocks ventilation, furniture covers air vents
用戶自檢
User Self‑Check
檢查櫃體上下後方通風口是否被遮蓋
Check top‑bottom‑rear air vents covered
處理方案
Solution
釋放散熱空間;清潔內置散熱模組
Release ventilation clearance; clean built‑in cooling module
維修更換零件
Replacement Parts
散熱模組(清潔維護)
Cooling module (cleaning maintenance)
故障:酒櫃不停機 24 小時長期運轉
Fault: Wine cooler runs 24‑hours non‑stop, never cuts off
+
原因分析
Cause
門封漏冷、設定溫度過低、感應器失效
Door gasket cold‑leakage, set temperature too low, sensor failure