檢查插蘇、電掣是否跳掣、插座有無電;機身側 / 底部水箱滿水浮波卡住,取出水箱重新放穩;門蓋 / 濾網蓋未關實,安全開關斷電,蓋緊再試;長按電源鍵 10 秒重置機器。仍無反應:電源板、變壓器故障,需維修。
Check power socket & circuit breaker. Reset water tank float. Close cover tightly. Long press power key for 10s to reset. If still no response, power board & transformer need repair.
抽出水箱,清洗內部浮球(浮波),撥動浮球看能否上下活動;水箱滑道有灰塵阻礙,抹乾淨、確保水箱完全推入卡實;浮球卡膠、斷裂:更換浮球配件。
Clean water tank float. Clear dust on tank rail. Replace broken float parts immediately.
室溫低於 16℃,壓縮機會凍結停機,屬保護;濾網、蒸發器灰塵堵塞,拆出濾網水洗、風葉擦乾淨;設定濕度太高,調至 45–55%;關閉門窗;仍不抽濕:雪種漏、壓縮機故障。
Low temperature protection. Clean filter & evaporator. Adjust humidity to 45-55%. Refrigerant leakage & compressor failure need professional repair.
關機開風扇模式運行 2–3 小時自然融霜,切勿用熱水沖機內;清洗濾網;提升室溫;保持機身四周 10cm 散熱空間。持續結霜:溫度感應器故障。
Natural defrost only, DO NOT use hot water. Keep ventilation space. Faulty temperature sensor causes continuous frosting.
檢查定時功能是否開啟,關閉定時;濕度感應器積灰清潔;更換插座測試;移開散熱口障礙物。
Turn off timer function. Clean humidity sensor. Change power socket. Keep air vent unobstructed.
擺放地面不平,墊防滑墊調平機身;水箱未卡緊、風葉沾灰失衡;機底膠腳磨損;清理風扇毛髮。金屬撞擊聲:風扇馬達、壓縮機故障。
Level machine position. Clean fan blades. Replace rubber feet. Metal knocking noise means motor & compressor damage.
機內接水盤淤塞灰塵 / 黴菌,清水沖走排水槽髒物;水箱密封圈發霉老化更換;拉直連續排水喉。
Unclog drain pan & mold. Replace aging sealing ring. Straighten drain hose.
清洗濾網陰乾;白醋擦拭蒸發器、接水盤;清空水箱開風乾模式;每月定期自潔保養。
Wash & dry filter. Clean evaporator with vinegar. Run drying mode regularly to remove mold smell.
濾網嚴重堵塞過熱保護;關機冷卻1小時清洗;風扇馬達、風扇電容損壞需更換。
Overheat protection due to blocked filter. Replace fan motor & capacitor.
擦乾面板水氣油污;斷電5分鐘重置;手部潮濕會觸控失靈;全部無效:控制面板故障。
Wipe dry panel surface. Power reset. Broken control panel needs replacement.
斷電5分鐘重啟主板;溫濕度異常誤報;持續報錯:感應器、主板故障維修。
Reset mainboard. Abnormal sensor causes error code display.
縮小密封空間;清洗堵塞濾網;手動調最低濕度45%使用。
Use in closed small room. Clean filter & set lowest humidity level.
長按切換靜音模式;調平機身減震;清理風扇纏繞毛髮。
Long press to activate silent mode. Adjust machine balance & clean fan hair.
乾毛刷清潔放電針;重新開啟功能;模組損壞更換零件。
Clean ion discharge needle. Replace damaged negative ion module.
沖洗喉管淤塞污垢;保持喉管向下傾斜;清理機身內排水口棉絮雜物。
Flush blocked hose. Keep hose sloping downward. Unclog drain outlet.
清空進出風口障礙;定期清洗濾網;連續運作8小時後休息散熱。
Keep vents clear. Clean filter regularly. Rest machine after long continuous operation.
定期清潔散熱濾網;緊閉門窗;低溫影響壓縮效率;長期衰減多為雪種微量洩漏。
Dust blockage & refrigerant slow leakage cause weaker dehumidifying effect.
輕微流水聲屬製冷劑正常流動;伴隨漏水則清理淤塞接水盤。
Normal refrigerant flow sound. Clean drain pan if water leaks accompany noise.
清洗濾網;移開出風口雜物;高溫環境移至陰涼位置使用。
Clean filter, keep vent clear. Move unit to cool place in hot weather.
沖洗水箱浮球黴菌;擦拭金屬接觸點;斷電10分鐘重啟;閒置前清空水箱風乾保養。
Clean stuck float switch. Reset power supply. Drain water before long storage.
所有清潔、檢查前必須拔插蘇斷電;機內結霜只可自然融冰,嚴禁熱水、風筒直吹;不可自行拆壓縮機、雪種管路,涉及制冷系統需官方維修;每月清濾網、每季度清洗接水盤,大幅減少故障。
Always unplug power before maintenance. Do not use hot water to defrost. Do not disassemble compressor & refrigerant pipeline. Clean filter monthly to reduce faults.
漏雪種、完全不抽濕;壓縮機異響、無法啟動;主板、感應器、風扇馬達損壞;內部管路漏水、零件斷裂。
Refrigerant leakage, no dehumidification, strange compressor noise, mainboard damage, internal water leakage & broken parts.
涵蓋韓系、歐洲、香港本土行貨、內地家用地下室工業抽濕機、迷你半導體除濕機、商用倉庫大功率抽濕機全型號維修保養
Korean, European, Hong Kong local, household, basement, industrial & mini semiconductor dehumidifier full model repair service
地址:香港九龍觀塘駿業裏10號業運工業大廈5D
Address: Unit 5D Yip Wan Industrial Building, 10 Chun Yip Lane Kwun Tong Kowloon HK
☎ 電話 Tel:5531 1921|6764 5053
???? 郵箱 Email:haolong2002@gmail.com
???? 官網 Website:https://www.hkrepair999.com/