A:多數係電源板燒毀、保險絲燒斷、插頭供電異常。先檢查插座有沒有電;若供電正常機器毫無反應,需要維修師傅檢測更換電源主板,全港可上門檢測。
EN: Mostly burnt power board, blown fuse or power supply fault. Check wall socket first. If power is ok but unit dead, need onsite inspection & power board replacement. Service available Hong Kong wide.
A:常見雪種泄漏、製冷管路漏氣。壓縮機轉但無冷氣,不要長時間開機,需要師傅做管路測漏、抽真空、重新加注雪種,觀塘、九龍、新界均可上門處理。
EN: Refrigerant gas leak in cooling pipe. Compressor runs but no cooling. Do not keep running. Need leak test, vacuum & gas refill. On‑site service Kwun Tong, Kowloon, New Territories.
A:E1 代表溫度感應器故障老化。感應器讀數錯亂令酒櫃無法控溫,一般直接更換對應溫度傳感器即可現場維修。
EN: Error E1 = defective temperature sensor. Wrong temperature reading causes cooling failure. Sensor replacement can be done on‑site.
A:LL 低溫報錯,多為溫度傳感器短路或者主控板訊號異常。會出現過度製冷、櫃內結厚霜,需要檢查傳感器線路及更換零件。
EN: LL error = over‑cooling fault. Caused by shorted sensor or main board signal error. Heavy frost inside cabinet. Need wiring check & part replacement.
A:HH 代表偵測到櫃內溫度過高。原因有門封漏冷、風扇不轉、冷凝器積灰散熱差、壓縮機故障。先檢查門有沒有關緊,仍然報警就要上門維修。
EN: HH high‑temperature beep alarm. Causes: bad door seal, broken fan, dusty condenser, compressor fault. Check door closed properly first. If alarm persists book onsite repair.
A:雙溫區最常壞係內循環風扇摩打損壞,冷氣無法送到另一個溫區。風扇不轉就會出現單邊不製冷,現場可以更換風扇零件。
EN: Dual‑zone wine cooler one side no cooling. Common fault: internal circulation fan motor broken. Fan replacement available onsite.
A:主要來源:風扇摩打磨損、壓縮機腳膠老化鬆動、管路互相撞擊。檢查是否擺放不平;噪音持續就要維修更換故障風扇或調整壓縮機避震。
EN: Loud noise & vibration from fan wear, aged compressor rubber mount or pipe collision. Check level placement. Replace fan or adjust compressor mounting if noise continues.
A:排水孔堵塞、門封膠條老化漏冷,導致櫃外同內部大量凝露滴水。先清通排水孔;膠條老化就要更換門封,解決漏冷滴水問題。
EN: Water leakage & condensation. Drain hole blocked or worn door gasket. Clear drain hole first; replace gasket if seal is damaged.
A:多為壓縮機啟動電容老化衰減,電容出力不穩,造成壓縮機斷斷續續工作。更換啟動電容多數可以解決此故障。
EN: Intermittent cooling. Usually aged compressor start capacitor. Replace capacitor to fix most cases.
A:除霜系統異常、除霜感應器故障、門密封不良濕氣持續入櫃。厚霜會阻礙製冷效果,需要維修檢查除霜感應器同主控板。
EN: Heavy frost / ice build‑up. Defrost system or defrost sensor failure, poor door seal. Need inspect defrost sensor & main control board.
A:內置循環風扇摩打燒毀,就算壓縮機正常,冷氣散不出來。表現壓縮機一直轉但降溫慢,現場可更換風扇組件。
EN: Internal circulation fan dead. Compressor runs but poor cooling. Fan assembly replacement onsite.
A:顯示面板故障或者主控板接觸不良。溫度讀數跳動無法正常設定溫度,需要檢查排線、更換顯示板或者主控電路板。
EN: Display flickering, garbled digits. Fault display panel or loose main board wiring. Check ribbon cable, replace display or main PCB.
A:嵌入式機型最常見散熱空間不足,後面同兩側散熱位被封死,壓縮機過熱保護。先確保機身留有散熱空位,故障依舊就要檢查壓縮機同雪種。
EN: Built‑in wine cooler poor cooling. Insufficient ventilation space triggers compressor overheat protection. Leave ventilation gap; inspect compressor & refrigerant if still faulty.
A:壓縮機卡缸、啟動電容損壞。會聽到嗡嗡聲之後跳保護,機器無法進入製冷。需要師傅現場判斷更換電容或者壓縮機。
EN: Compressor hums but cannot start. Compressor stuck rotor or bad start capacitor. Technician onsite to replace capacitor or compressor unit.
A:Wino 酒櫃過保後原廠維修收費昂貴,可找專修紅酒櫃師傅,處理 E1/E3/HH/LL、不製冷、漏水、風扇、壓縮機、傳感器等故障,觀塘、九龍、香港島、新界均可提供上門檢查報價。
EN: Out‑of‑warranty Wino wine cooler repair. We handle E1 E3 HH LL error codes, no cooling, water leak, fan, compressor & sensor faults. On‑site inspection & quotation Kwun Tong, Kowloon, HK Island, New Territories.
WhatsApp /電話講述酒櫃型號、故障現象、報錯代碼、地址,預約上門時間。
技師按約定時間到場,做全面檢測,找出故障源頭,提供維修報價。
講解故障原因、零件費用、人工費,客戶同意才開始維修作業。
更換故障零件、測漏、加注雪種、調試機器,現場測試運行。
確認酒櫃運作正常、報警消除,交付客戶,完成維修。
Wino紅酒櫃HH高溫嗶嗶報警,師傅上門檢查發現冷凝器積灰加風扇損壞,更換風扇清潔散熱系統,機器恢復正常製冷。
— 九龍觀塘客戶
Wino酒櫃彈E1故障代碼,溫度亂跳。現場更換溫度感應器,半小時完成,溫控恢復穩定。價錢合理。
— 新界沙田客戶
雙溫區Wino酒櫃一邊唔凍,判斷內循環風扇壞,現場更換零件,兩個溫區回復正常溫度。
— 香港島灣仔客戶
過保Wino酒櫃壓縮機轉但不製冷,雪種泄漏,做測漏抽真空加雪種,酒櫃降溫正常。
— 將軍澳客戶
維修| 維諾卡夫、芭克斯、哈士奇、西門子、美的、海爾、卡薩帝、索菲亞、新朝、富客等品牌專屬服務
中西區:中環、上環、西營盤、堅尼地城、山頂
灣仔區:灣仔、銅鑼灣、跑馬地、大坑、會展中心
東區:北角、鰂魚涌、筲箕灣、柴灣
南區:香港仔、鴨脷洲、深水灣、淺水灣、赤柱
油尖旺:油麻地、尖沙咀、旺角
深水埗:深水埗、長沙灣、荔枝角
九龍城:九龍城、九龍塘、何文田、紅磡
黃大仙:黃大仙、慈雲山、樂富、新蒲崗
觀塘區:觀塘市中心、藍田、將軍澳
荃灣:荃灣市區、馬灣島
屯門、元朗:元朗市區、天水圍、鄉郊
北區:上水、粉嶺、打鼓嶺
大埔:大埔墟、吐露港、船灣淡水湖
沙田:沙田市區、大圍、馬鞍山
西貢:西貢市、將軍澳