商業電器維修:5531 1921 家庭電器維修:6764 5053 維修售後支援:5445 4474
A:多數係電源板燒毀、保險絲燒斷、插頭供電異常。先檢查插座有沒有電;若供電正常機器毫無反應,需要維修師傅檢測更換電源主板,全港可上門檢測。
A: Usually caused by burnt power board, blown fuse or wall socket fault. Check wall outlet first. If power supply is normal but unit dead, technician needs to inspect & replace main power board. On‑site service available across Hong Kong.
A:常見雪種泄漏、製冷管路漏氣。壓縮機轉但無冷氣,不要長時間開機,需要師傅做管路測漏、抽真空、重新加注雪種,觀塘、九龍、新界均可上門處理。
A: Refrigerant gas leak or cooling pipe leakage is common. Do not keep running the unit. Technician will perform leak test, vacuum and refrigerant recharge. On‑site service for Kwun Tong, Kowloon, New Territories.
A:E1 代表溫度感應器故障老化。感應器讀數錯亂令酒櫃無法控溫,一般直接更換對應溫度傳感器即可現場維修。
A: E1 means defective temperature sensor. Wrong reading causes temperature control failure. On‑site replacement of temperature sensor is available.
A:LL 低溫報錯,多為溫度傳感器短路或者主控板訊號異常。會出現過度製冷、櫃內結厚霜,需要檢查傳感器線路及更換零件。
A: LL is low‑temperature alarm. Usually shorted temperature sensor or main board signal fault. Unit over‑cools with heavy frost. Need wiring inspection & component replacement.
A:HH 代表偵測到櫃內溫度過高。原因有門封漏冷、風扇不轉、冷凝器積灰散熱差、壓縮機故障。先檢查門有沒有關緊,仍然報警就要上門維修。
A: HH = high internal temperature. Causes: bad door seal, broken fan, dusty condenser, compressor fault. Check door closed tightly. If alarm persists book on‑site repair.
A:雙溫區最常壞係內循環風扇摩打損壞,冷氣無法送到另一個溫區。風扇不轉就會出現單邊不製冷,現場可以更換風扇零件。
A: Most common fault: internal circulation fan motor failure. Cold air cannot circulate to second zone. Fan assembly can be replaced on‑site.
A:主要來源:風扇摩打磨損、壓縮機腳膠老化鬆動、管路互相撞擊。檢查是否擺放不平;噪音持續就要維修更換故障風扇或調整壓縮機避震。
A: Sources: worn fan motor, aged compressor rubber mounts, pipe collision. Check unit level. Persistent noise requires fan replacement or compressor anti‑vibration adjustment.
A:排水孔堵塞、門封膠條老化漏冷,導致櫃外同內部大量凝露滴水。先清通排水孔;膠條老化就要更換門封,解決漏冷滴水問題。
A: Blocked drain hole or worn door gasket causes condensation & dripping. Clean drain hole first. Replace door seal gasket if aged.
A:多為壓縮機啟動電容老化衰減,電容出力不穩,造成壓縮機斷斷續續工作。更換啟動電容多數可以解決此故障。
A: Usually ageing compressor start capacitor, unstable power output causes intermittent running. Replace start capacitor to resolve most cases.
A:除霜系統異常、除霜感應器故障、門密封不良濕氣持續入櫃。厚霜會阻礙製冷效果,需要維修檢查除霜感應器同主控板。
A: Defrost system fault, defective defrost sensor or bad door seal letting moisture inside. Heavy frost blocks cooling. Need inspection for defrost sensor & main control board.
A:內置循環風扇摩打燒毀,就算壓縮機正常,冷氣散不出來。表現壓縮機一直轉但降溫慢,現場可更換風扇組件。
A: Burnt‑out circulation fan motor. Compressor runs but cold air cannot circulate, slow temperature drop. Fan assembly replacement on‑site available.
A:顯示面板故障或者主控板接觸不良。溫度讀數跳動無法正常設定溫度,需要檢查排線、更換顯示板或者主控電路板。
A: Defective display panel or loose main‑board wiring. Temperature value jumps, cannot set temperature normally. Need wiring check, replace display board or main circuit board.
A:嵌入式機型最常見散熱空間不足,後面同兩側散熱位被封死,壓縮機過熱保護。先確保機身留有散熱空位,故障依舊就要檢查壓縮機同雪種。
A: Built‑in model common fault: insufficient ventilation space, blocked heat dissipation causes compressor overheat protection. Keep ventilation gap. If problem persists inspect compressor & refrigerant gas.
A:壓縮機卡缸、啟動電容損壞。會聽到嗡嗡聲之後跳保護,機器無法進入製冷。需要師傅現場判斷更換電容或者壓縮機。
A: Compressor locked rotor or faulty start capacitor. Humming sound then safety cut‑off. Technician onsite to replace capacitor or compressor accordingly.
A:Wino 酒櫃過保後原廠維修收費昂貴,可找專修紅酒櫃師傅,處理 E1/E3/HH/LL、不製冷、漏水、風扇、壓縮機、傳感器等故障,觀塘、九龍、香港島、新界均可提供上門檢查報價。
A: Original manufacturer out‑of‑warranty repair is expensive. Our technician handles E1/E3/HH/LL error, no cooling, water leak, fan, compressor, sensor faults. On‑site inspection & quotation for Kwun Tong, Kowloon, HK Island, New Territories.
WhatsApp /電話講述酒櫃故障、報錯代碼、地址,預約上門時間。
Tell us fault symptoms, error code & location via WhatsApp or phone, book appointment.
到場全面檢查電路、壓縮機、風扇、傳感器、雪種狀態,找出故障源頭。
Full check of circuit, compressor, fan, sensor, refrigerant to locate root cause.
檢測完畢提供維修報價,客戶同意先收檢測費,再展開維修。
Provide repair quotation after inspection. Repair starts after client approval.
更換損壞零件:風扇、傳感器、電容、電源板、門封、加注雪種等。
Replace broken parts: fan, sensor, capacitor, power board, door seal, refrigerant recharge etc.
運行測試溫度、製冷、報警功能,確認故障完全解決。
Test cooling, temperature & alarm function to confirm fault resolved.
檢測電壓、電阻,測試電源板、傳感器、風扇摩打好壞。
Test voltage & resistance, diagnose power board, sensor & fan motor.
檢測雪種管路洩漏位置。
Locate refrigerant gas leak points.
維修製冷管路後抽真空,準備加注雪種。
Pull vacuum for refrigeration piping before gas recharge.
監控雪種壓力,精準加注製冷劑。
Monitor pressure for accurate refrigerant charging.
核對酒櫃實際內部溫度是否正常。
Verify actual internal cabinet temperature.
拆裝機殼、更換風扇、電路板、門封膠條。
Disassemble cabinet, replace fan, circuit board, door gasket.
Wino雙溫酒櫃一邊唔凍,確認係內循環風扇壞,師傅現場更換風扇,當日修復,而家兩邊溫度正常。
Wino dual‑zone cooler one‑side not cold. Confirmed bad circulation fan, replaced on‑site same day. Both zones temperature working properly now.
酒櫃彈E1故障代碼,溫度亂跳。更換溫度感應器解決,報價透明,上門速度快。
Wine cooler shows E1 error with erratic temperature. Replaced temperature sensor, quotation transparent, fast on‑site arrival.
酒櫃底部漏水同結厚霜,檢查係門封老化同排水孔阻塞。處理完滴水問題完全消失。
Wine cooler bottom water leak & heavy frost. Bad door seal & blocked drain hole. After repair dripping problem fully solved.
香港島
中西區:中環、上環、西營盤、堅尼地城、山頂
灣仔區:灣仔、銅鑼灣、跑馬地、大坑、會展中心
東區:北角、鰂魚涌、筲箕灣、柴灣
南區:香港仔、鴨脷洲、深水灣、淺水灣、赤柱
九龍
油尖旺區:油麻地、尖沙咀、旺角
深水埗區:深水埗、長沙灣、荔枝角
九龍城區:九龍城、九龍塘、何文田、紅磡
黃大仙區:黃大仙、慈雲山、樂富、新蒲崗
觀塘區:觀塘市中心、藍田、將軍澳
新界
荃灣區:荃灣市區、馬灣島
屯門、元朗區:元朗市區、天水圍、鄉郊
北區:上水、粉嶺、打鼓嶺
大埔區:大埔墟、吐露港、船灣淡水湖
沙田區:沙田市區、大圍、馬鞍山
西貢區:西貢市、將軍澳
Hong Kong Island
Central‑Western, Wan Chai, Eastern, Southern District
Kowloon
Yau Tsim Mong, Sham Shui Po, Kowloon City, Wong Tai Sin, Kwun Tong
New Territories
Tsuen Wan, Tuen Mun, Yuen Long, North District, Tai Po, Sha Tin, Sai Kung
地址:香港九龍觀塘駿業裏10號業運工業大廈5D
營業時間:星期一至星期六
電話:55311921 | 67645053
電郵:haolong2002@gmail.com
Address: 5D, Yip Wan Industrial Building, 10 Tsun Yip Lane, Kwun Tong, Kowloon, Hong Kong
Business Hours: Monday‑Saturday
Tel: 55311921 | 67645053
Email: haolong2002@gmail.com
Website: https://www.hkrepair999.com/