商業電器維修:5531 1921 家庭電器維修:6764 5053 維修售後支援:5445 4474
香港專業團隊 · 全港上門維修 · 價格透明 · 質量保證 Professional Team in Hong Kong · On-site Service · Transparent Price · Quality Guarantee
WhatsApp 立即預約 | Book Now風扇是酒櫃恆溫核心,故障會導致冷氣無法對流,出現局部不凍、溫度不均等問題
Vinorich Wine Cooler Partial Cooling Failure | Repair for Abnormal Refrigeration Circulation Caused by Fan Fault
內循環風扇馬達燒毀、風扇葉片卡異物、風扇供電線路鬆脫、主控板風扇輸出故障
Internal circulation fan motor burnout, fan blade jammed by foreign objects, loose fan power supply wiring, main control board fan output failure
貼近酒櫃聽是否有風扇轉動聲音;打開門觀察風扇葉片是否停滯;檢查出風口是否有冷風吹出
Listen close to the wine cooler for fan running sound; open the door to check if fan blades are stationary; verify if cold air blows from the air outlet
清理風扇異物灰塵;檢修風扇供電線路;更換原廠風扇馬達;檢修主控板控制模組
Clean foreign objects and dust from the fan; repair fan power supply lines; replace original fan motor; repair main control board module
一般故障1-2小時現場完成;如需更換特殊零件,預約零件後次日完成
Common faults completed on-site in 1-2 hours; if special parts need replacement, finished next day after parts reservation
點擊故障標題查看詳細原因、自檢方法與專業維修方案 | Click on fault titles for details
壓縮機故障、雪種洩漏、散熱塵垢過多 Compressor failure, refrigerant leakage, excessive dust on heat dissipation fins
檢查背後散熱位是否被雜物阻擋,門有冇關實 Check if rear heat dissipation area is blocked by debris, and if the door is fully closed
清潔散熱網;雪種測漏加註;損壞需更換壓縮機 Clean heat dissipation grille; detect refrigerant leakage and refill; replace compressor if damaged
溫度感應器老化、風扇循環異常、門封漏冷 Aging temperature sensor, abnormal fan circulation, cold air leakage from door seal
觀察門膠條是否有縫隙,內籠風扇有無轉動 Check if door rubber strip has gaps, and if internal fan is running
更換溫度感應器;維修循環風扇;替換老化門封膠條 Replace temperature sensor; repair circulation fan; replace aging door seal rubber strip
電源板故障、保險絲燒毀、電路接線鬆脫 Power board failure, fuse blown, loose circuit wiring
插座測試有冇電,電源插頭是否插穩 Test if the socket has power, and if the power plug is securely inserted
檢查更換保險絲;維修電源主板;重接鬆脫線路 Check and replace fuse; repair power supply main board; reconnect loose wiring
顯示面板故障、接觸線鬆動、主板供電異常 Display panel failure, loose connection cable, abnormal main board power supply
重新斷電重啟 5 分鐘再開機測試 Power off and restart after 5 minutes for testing
重新插接排線;維修或更換觸控顯示面板 Reconnect flat cable; repair or replace touch display panel
觸摸面板受潮老化、主板控制模組損壞 Moisture damage or aging of touch panel, damaged main control module
抹乾面板表面水氣,斷電重啟測試 Wipe off moisture on panel surface, power off and restart for test
清潔檢查排線;必要更換整套觸控面板 Clean and inspect flat cable; replace entire touch panel if necessary
門未關妥、溫度超標、故障代碼觸發警報 Door not closed properly, temperature over limit, fault code triggered alarm
關緊櫃門,查看屏幕有冇彈出錯誤代碼 Close the door tightly, check if error code appears on screen
排除門關閉問題;讀取故障代碼維修對應零件 Resolve door closing issue; read fault code and repair corresponding parts
分區風扇損壞、擋風隔板移位、控溫感應器故障 Damaged zone fan, displaced air baffle, temperature control sensor failure
檢查內籠擋板有冇被酒瓶擋住出風口 Check if internal baffle air outlet is blocked by wine bottles
維修分區循環風扇;更換對應溫度感應器 Repair zone circulation fan; replace corresponding temperature sensor
除霜系統失效、門封漏氣、濕度過高 Defrost system failure, door seal air leakage, excessive humidity
停機解凍,檢查門膠條有冇漏冷氣 Power off to defrost, check if door rubber strip leaks cold air
維修除霜感應器;更換門封膠圈 Repair defrost sensor; replace door seal gasket
排水孔堵塞、排水管脫落、凝水盤滿溢 Clogged drain hole, fallen drain pipe, overflowing condensate pan
查看底部接水盤是否水滿,清理排水孔異物 Check if bottom water tray is full, clean foreign objects from drain hole
疏通排水管路;重新安裝脫落排水管 Unclog drain pipeline; reinstall fallen drain pipe
壓縮機腳膠老化、風扇葉片碰殼、零件鬆動 Aging compressor rubber feet, fan blade hitting casing, loose parts
檢查酒櫃是否擺放水平,背後有冇牆面碰撞 Check if wine cooler is placed level, if rear hits the wall
更換減震膠腳;維修更換故障風扇馬達 Replace shock-absorbing rubber feet; repair or replace faulty fan motor
門鉸磨損、門封膠條變形老化 Worn door hinge, deformed and aging door seal rubber strip
用紙張夾在門縫測試,紙可輕易抽出即漏冷 Test with paper in door gap; if paper pulls out easily, cold air is leaking
調校門鉸;更換全新門封膠條 Adjust door hinge; replace brand new door seal rubber strip
散熱位被封死、環境溫度太高、連續長時間運轉 Blocked heat dissipation area, high ambient temperature, continuous long-time operation
確保機身四周預留 10cm 以上散熱空間 Ensure at least 10cm heat dissipation space around the machine
清理散熱網塵埃;改善周邊通風環境 Clean dust from heat dissipation grille; improve surrounding ventilation
LED 燈條燒壞、燈具接線鬆脫 Burned LED light strip, loose lamp wiring
斷電後輕搖燈帶位置,重啟測試 Gently shake the light strip after power off, restart for test
重新接駁線路;更換 LED 照明燈條 Reconnect wiring; replace LED lighting strip
壓縮機短路、電容損壞、電路受潮短路 Compressor short circuit, damaged capacitor, damp circuit short circuit
不要反覆重啟,避免擴大故障 Do not restart repeatedly to avoid worsening the fault
檢測壓縮機與啟動電容,更換損壞零件 Test compressor and starting capacitor, replace damaged parts