De'Longhi Eletta Art 20大常見故障維修Q&A
20 Common Faults for De'Longhi Eletta Art Q&A
Q1德龍咖啡機機底漏水、滴水盤經常積水,是什麼問題?Machine bottom leaking, drip tray fills quickly
+
故障現象:沖洗或製作咖啡時機身底部滲水,滴水盤短時間就積滿水。
故障原因:矽膠軟管老化破裂、沖煮組密封圈硬化、熱交換器積垢滲漏、水箱底部止水閥損壞。
自行檢查方法:檢查水箱底膠閥狀態、定期拆解清洗沖煮組、執行完整除垢程序。
維修更換零件:矽膠水管、沖煮組密封圈、水箱底止水閥。
Symptom: Water leaks under machine during rinse/brewing, drip tray fills rapidly.
Causes: Aged silicone tube crack, brew group seal hardened, heat exchanger scale leakage, tank bottom valve damaged.
Self-check: Inspect tank valve, clean brew group regularly, complete descaling cycle.
Replacement Parts: Silicone tube, brew group gasket, tank shut-off valve.
Q2水箱有水,但機器持續閃缺水提示 FILL TANK,如何維修?Tank full but machine shows FILL TANK warning
+
故障現象:水箱已經加滿清水,儀表仍然提示缺水,有時做完一杯咖啡立刻報警。
故障原因:水位浮子卡滯或破損、水流感應器故障、水箱接觸位髒汙導致感應失靈。
自行檢查方法:取出水箱清洗水位浮球,擦乾機身與水箱接觸觸點。
維修更換零件:水位浮子總成、水流傳感器(水表)。
Symptom: Water tank full yet "FILL TANK" alert appears, triggers after single shot.
Causes: Stuck/broken float, flow sensor failure, dirty contact points.
Self-check: Remove tank, clean float ball, wipe contact terminals.
Replacement Parts: Float assembly, flow meter sensor.
Q3德龍咖啡機磨豆機不轉、卡豆、研磨時發出異響?Grinder not spinning, stuck beans, abnormal noise
+
故障現象:切換咖啡豆模式,磨豆馬達沒有反應,或是出現金屬異響,無法正常下豆研磨。
故障原因:咖啡豆油脂黏附刀盤造成堵塞、異物卡入刀盤、磨豆馬達燒毀、傳動齒輪卡阻。
自行檢查方法:清空豆倉清理咖啡油垢,禁止空機狀態調校研磨粗細。
維修更換零件:磨豆馬達、磨豆刀盤、研磨傳動齒輪。
Symptom: Grinder motor no response, metal noise, unable grind coffee beans.
Causes: Oil residue block burrs, foreign object jam, burnt motor, jammed gear.
Self-check: Empty hopper, clean coffee grease. Do not adjust grind while empty.
Replacement Parts: Grinder motor, burr set, drive gear.
Q4咖啡出水量不穩定,同一設定有時多、有時少?Unstable coffee output volume with same setting
+
故障現象:固定咖啡份量設定,萃取水量忽多忽少,無法穩定定量。
故障原因:水流感應器老化、內部水路水垢堵塞、水泵壓力衰退。
自行檢查方法:執行完整除垢,多次啟動自動沖洗清理水路。
維修更換零件:水流感應水表、電磁閥、震動水泵。
Symptom: Inconsistent shot volume under identical settings.
Causes: Aging flow sensor, limescale blockage, weak pump pressure.
Self-check: Full descaling, run auto rinse repeatedly.
Replacement Parts: Flow meter, solenoid valve, vibration pump.
Q5沖出來的咖啡不夠熱、出水溫度偏低怎麼處理?Coffee temperature too low, insufficient heat
+
故障現象:機器顯示備妥 READY,但咖啡溫度偏涼,蒸汽溫度不足。
故障原因:NTC 溫度感應器故障、加熱熱塊堆積大量水垢、溫控保護跳脫。
自行檢查方法:善用預沖洗功能、定期除鈣、萃取前預熱咖啡杯。
維修更換零件:NTC 溫度探針、加熱熱塊、熱保護器。
Symptom: Machine READY but coffee cool, weak steam temperature.
Causes: Faulty NTC sensor, scale blocked thermoblock, thermal protection tripped.
Self-check: Pre-rinse, regular descaling, preheat cups.
Replacement Parts: NTC probe, thermoblock, thermal fuse protector.
Q6咖啡機無法產生蒸汽、蒸汽出力弱,只有熱水沒有蒸氣?No steam, weak steam, only hot water from steam wand
+
故障現象:切換蒸汽模式,只能流出熱水,產生不了蒸汽,難以打奶泡。
故障原因:蒸汽管路水垢淤塞、蒸汽電磁閥卡滯、水泵壓力不足、蒸汽噴嘴堵塞。
自行檢查方法:拆解清洗蒸汽棒,定期執行完整除垢程序。
維修更換零件:蒸汽電磁閥、蒸汽噴嘴套件、水泵。
Symptom: Steam mode outputs hot water only, cannot foam milk.
Causes: Scale clogged steam path, stuck steam solenoid, low pump pressure, blocked nozzle.
Self-check: Disassemble & clean steam wand, full descaling cycle.
Replacement Parts: Steam solenoid, steam nozzle kit, water pump.
Q7自動奶泡系統打出奶泡稀薄、泡沫粗大,吸奶管不吸牛奶?Auto milk frother weak foam, suction tube no milk intake
+
故障現象:卡布奇諾系統噴濺、奶泡容易消散,吸管無法抽取牛奶。
故障原因:奶泡管路、奶泡頭累積奶垢堵塞、進氣孔封閉。
自行檢查方法:每次使用完即清洗整套奶泡配件,拆解沖洗所有管路。
維修更換零件:奶泡吸管、奶泡頭、奶泡閥組。
Symptom: Splatters, unstable foam, milk suction failure.
Causes: Milk residue block tube, air inlet blocked.
Self-check: Clean all milk components after every use.
Replacement Parts: Milk suction tube, frother head, milk valve assembly.
Q8機器出現三角形嘆號、GENERAL ALARM 通用故障警報?Triangle warning sign, GENERAL ALARM error
+
故障現象:螢幕亮起通用故障警示,無法製作咖啡。
故障原因:沖煮組位置偏移、傳動馬達卡滯、機內過髒、主板訊號異常。
自行檢查方法:斷電關機,取出沖煮組清潔後重新正確安裝。
維修更換零件:沖煮組傳動馬達、位置感應開關。
Symptom: General alarm triggered, machine stops brewing.
Causes: Misaligned brew group, jam drive motor, dirty interior, mainboard signal error.
Self-check: Power off, remove, clean and reinstall brew group.
Replacement Parts: Brew group drive motor, position sensor switch.
Q9沖煮組(萃取器)卡住,沒辦法取出,硬拉會損壞嗎?Brew group stuck, cannot be pulled out
+
故障現象:無法拉出沖煮組,關機之後仍然卡緊。
故障原因:沖煮組停留在非拆卸位置、咖啡粉結塊卡阻、傳動齒輪磨損。
自行檢查方法:務必在完全斷電狀態嘗試取出,禁止強行拉扯。
維修更換零件:沖煮組總成、傳動齒輪組。
Symptom: Brew group locked, unable to remove after power off.
Causes: Group not at service position, compacted coffee powder, worn drive gear.
Self-check: Fully power off first, NEVER pull hard manually.
Replacement Parts: Complete brew group, drive gear set.
Q10咖啡一滴一滴緩慢流出、萃取速度很慢,咖啡味道苦澀?Slow dripping coffee, bitter over-extraction
+
故障現象:出水細小呈滴漏狀,萃取時間過長。
故障原因:水路水垢、咖啡出水口噴嘴堵塞;半自動機型常見濾碗堵塞、沖煮頭膠圈積垢。
自行檢查方法:清理出水口噴嘴、完整除垢,嘗試調粗研磨度測試。
維修更換零件:出水噴嘴、電磁閥。
Symptom: Slow drip, overly long extraction time, bitter taste.
Causes: Limescale & clogged spout, portafilter clog for semi-auto models.
Self-check: Clean spout, full descaling, try coarser grind.
Replacement Parts: Coffee spout nozzle, solenoid valve.
Q11雙出水口只有單邊出咖啡,另一邊完全不出水?Dual spout only one side dispenses coffee
+
故障現象:咖啡機雙噴嘴其中一側沒有咖啡流出。
故障原因:噴嘴累積乾硬咖啡油垢造成堵塞。
自行檢查方法:使用軟刷小心清理噴孔,養成定期沖洗習慣。
維修更換零件:咖啡出水口噴嘴總成。
Symptom: One spout dry, only single side pour coffee.
Causes: Dried coffee grease blocks nozzle hole.
Self-check: Soft brush clean spout, regular rinse routine.
Replacement Parts: Dual coffee spout assembly.
Q12廢渣盒咖啡渣不多,卻持續提示需要清空渣盒?Small coffee waste triggers empty waste box alert
+
故障現象:少量咖啡渣就觸發滿渣警示,不能繼續製作咖啡。
故障原因:渣盒光感感應窗口髒汙、彈簧觸點開關老化。
自行檢查方法:擦拭渣盒感應窗口、清潔滴水盤觸點。
維修更換零件:光感感應器、彈簧觸點開關。
Symptom: Waste box alert even with minimal coffee puck.
Causes: Dirty optical sensor window, worn contact switch.
Self-check: Wipe sensor window & drip tray contacts.
Replacement Parts: Optical sensor, spring contact switch.
Q13水泵嗡嗡震動噪音很大,但是完全不出水?Pump loud humming, zero water output
+
故障現象:按下萃取鍵,水泵持續發出噪音,沒有水流產生。
故障原因:水路出現空氣鎖、水泵老化、進水濾網堵塞、電磁閥卡死。
自行檢查方法:開啟熱水功能排出管路空氣,檢查水箱進水濾網。
維修更換零件:震動水泵、進水濾網、電磁閥。
Symptom: Pump hums loudly, no water flows out.
Causes: Air lock, aging pump, blocked inlet filter, stuck solenoid.
Self-check: Run hot water to purge air, clean inlet filter.
Replacement Parts: Vibration pump, inlet filter, solenoid valve.
Q14面板按鍵失靈、燈號亂閃,機器會自動執行沖洗?Control panel unresponsive, random flashing lights
+
故障現象:觸控或實體按鍵沒有反應,有時候自行觸發指令。
故障原因:操作面板受潮、按鍵膜老化、面板排線氧化。
自行檢查方法:斷電靜置半小時,等待機身內部除濕。
維修更換零件:操作面板、面板連接排線。
Symptom: Buttons no response, random auto rinse trigger.
Causes: Moisture inside panel, aged membrane, oxidized cable.
Self-check: Power off and rest 30 mins to dehumidify.
Replacement Parts: Control panel, ribbon cable.
Q15咖啡機閒置時不停自動沖洗,耗費大量清水?Continuous auto rinse while idle, waste water
+
故障現象:開機、閒置階段持續自動沖水,無法停止。
故障原因:主板程式異常、溫度感應訊號不穩、水流感應器誤判。
自行檢查方法:斷電重啟,嘗試回復機器出廠設定。
維修更換零件:主控板、NTC 溫度感應器。
Symptom: Machine keeps auto rinsing during standby.
Causes: Mainboard firmware error, unstable NTC, false flow sensor reading.
Self-check: Power cycle, restore factory settings.
Replacement Parts: Main control board, NTC temperature sensor.
Q16EC685、EC9335 半自動機,把手周圍噴水漏水?EC685 / EC9335 semi-auto leak around portafilter
+
故障現象:萃取時不從濾碗出水,把手外圍噴濺咖啡。
故障原因:沖煮頭密封圈老化硬化、堆積咖啡垢失去密封性。
自行檢查方法:拆出沖煮頭密封圈清洗觀察彈性。
維修更換零件:沖煮頭密封圈(沖煮頭膠圈)。
Symptom: Water splashes outside portafilter instead of pouring from basket.
Causes: Hardened group head gasket covered by coffee residue.
Self-check: Remove gasket and inspect elasticity after cleaning.
Replacement Parts: Group head rubber gasket.
Q17預磨粉通道堵塞,使用咖啡粉模式無法正常萃取?Pre-ground coffee chute blocked, cannot brew powder coffee
+
故障現象:倒入咖啡粉不會落入沖煮組,咖啡味道偏淡甚至不出咖啡。
故障原因:粉槽累積油垢結塊,封閉進粉通道。
自行檢查方法:使用專用毛刷定期清理預磨粉通道。
維修更換零件:預磨粉導料通道套件。
Symptom: Pre-ground coffee stuck in chute, weak or zero output.
Causes: Oil residue caking blocks powder channel.
Self-check: Regular brush clean pre-ground chute.
Replacement Parts: Pre-ground coffee feed chute assembly.
Q18除垢程式無法完成,一直重複提醒需要除垢?Descaling cycle incomplete, descale alert persists
+
故障現象:跑完整套除垢流程,警示燈仍然持續閃爍。
故障原因:機內水垢過厚、除垢期間水位不足、水流感應計數異常。
自行檢查方法:除垢時水箱加水至 MAX 刻度,重新完整執行一次除垢。
維修更換零件:水流感應水表。
Symptom: Descaling finished yet warning light keeps flashing.
Causes: Excessive scale, insufficient water during cycle, flow meter counting error.
Self-check: Fill tank to MAX and redo full descaling.
Replacement Parts: Flow sensor meter.
Q19運作途中自動斷電、無預警關機,擱置一段時間才能重啟?Machine auto power off mid-operation, rest required to restart
+
故障現象:製作咖啡中途機器突然熄機,無法立刻開機。
故障原因:熱保護器過熱跳脫、主板供電故障、整流橋損壞。
自行檢查方法:機器保留散熱空間,不要緊貼牆壁擺放。
維修更換零件:熱保護保險絲、主板整流橋、電源板。
Symptom: Unexpected power cut during brewing, cannot restart immediately.
Causes: Thermal protector tripped, power board fault, broken rectifier bridge.
Self-check: Keep ventilation space, avoid placing against wall.
Replacement Parts: Thermal fuse, rectifier bridge, power supply board.
Q20萃取咖啡 crema 薄、味道偏淡,香氣不足?Thin crema, weak flavour, low aroma
+
故障現象:相同咖啡豆與研磨設定,咖啡口感如水,crema 稀少。
故障原因:磨豆刀盤磨損變鈍、水路輕微堵塞、沖煮組密封失效。
自行檢查方法:微調至更細研磨度測試,全面清洗沖煮組。
維修更換零件:磨豆刀盤、沖煮組密封圈。
Symptom: Watery espresso, thin crema under same grind & bean setting.
Causes: Worn grinder burrs, minor waterway blockage, leaky brew group seal.
Self-check: Try finer grind, fully clean brew group.
Replacement Parts: Grinder burr set, brew group gasket.