1. 雪茄櫃內持續產生異味、雪茄沾染臭味
1. Persistent bad odor inside cabinet, cigars absorb smell
+
故障原因:活性炭濾網飽和失效、櫃內積留煙油黴菌、排水盤髒汙、密封膠條發霉。
處理方案:更換全新活性炭濾網、全櫃拆解除霉清洗、消毒排水系統、替換老化膠條。
保養知識:每6-12個月定期更換濾網,每月擦拭內櫃與水盤。
Cause: Saturated activated carbon filter, mold & tar buildup, dirty drain tray, aged rubber seal mold.
Solution: Replace new carbon filter, full cabinet mold disinfection, drain system clean, new seal strip installation.
Maintenance Tip: Change filter every 6-12 months, wipe interior & water tray monthly.
2. Vinvautz維諾茨活性炭濾網完全失效無法吸附異味
2. Vinvautz original carbon filter fully ineffective
+
故障原因:濾網使用超過一年、長期高濕環境堵塞、灰塵黴菌覆蓋活性碳孔隙。
處理方案:更換原廠規格活性炭濾網,同步清潔濾網安裝槽風道。
保養知識:潮濕的香港環境建議8個月更換一次濾網。
Cause: Filter over 1 year usage, high humidity block pores, dust & mold cover carbon surface.
Solution: Install genuine size Vinvautz carbon filter, clean ventilation slot together.
Maintenance Tip: Replace filter every 8 months for humid HK climate.
3. 櫃內木板、雪茄葉片出現發霉白黴、綠黴
3. White/green mold grow on cabinet wood & cigar wrapper
+
故障原因:濕度長期超75%、排水系統堵塞積水、門封漏氣室外濕氣滲入。
處理方案:高溫蒸汽除霉消毒、疏通排水、更換門膠、校正恆濕模組。
Cause: Humidity over 75% long term, blocked drain tray, air leak from door seal.
Solution: Steam mold disinfection, drain unclog, new door seal, humidity module calibration.
4. 恆濕系統故障,濕度持續偏高/偏低無法穩定4. Humidity control broken, RH too high/low unstable+
濕度感測器老化、加濕水幫浦故障、蒸發片堵塞;維修感測器、清洗蒸發系統、更換水泵。
Aged RH sensor, humidifier pump failure, evaporator block; repair sensor, clean evaporate system, replace pump.
5. 溫控失靈,櫃內溫度忽冷忽熱無法維持16-20℃5. Temperature unstable, can’t keep 16-20°C storage range+
壓縮機啟動電容損壞、溫度探頭偏移、散熱風扇停轉;更換電容、校正探頭、維修風扇。
Compressor capacitor damage, temp sensor drift, cooling fan stop; replace capacitor, calibrate probe, fix fan.
6. 門密封膠條硬化漏氣,室外潮氣侵入破壞存煙環境6. Hardened door rubber seal causes air leak & humidity intrusion+
膠條長期氧化失去彈性;整圈更換專用耐候密封膠條,調整門鉸鏈緊密度。
Rubber oxidized & lose elasticity; full set weatherproof seal replacement + hinge adjustment.
7. 櫃底排水盤積水溢出,滲漏損壞傢俬地板7. Overflow drain tray leak damage floor & furniture+
排水管路堵塞、水盤裂損;疏通管路、修補或替換全新排水盤。
Blocked drain pipe, cracked tray; unclog pipe, repair or replace drain tray.
8. 運轉噪音巨大,壓縮機震動、風扇異響8. Loud running noise, compressor vibration & fan abnormal sound+
風扇軸承磨損、壓縮機避震墊老化、機體不平;更換軸承、避震墊、調整機腳水平。
Worn fan bearing, aged compressor shock pad, uneven placement; replace bearing & pad, level cabinet feet.
9. 顯示面板黑屏、亂碼、按鍵無反應9. Control panel black screen, error code, unresponsive buttons+
主板供電故障、觸控模組受潮;維修電路板、隔離防潮、替換控制面板。
Mainboard power failure, touch module moisture damage; circuit repair, moisture isolation, new control panel.
10. 壓縮機持續不停機,過度製冷凍傷雪茄10. Compressor run nonstop, overcool burn cigars+
溫控繼電器損壞、冷媒不足;更換繼電器、檢測冷媒壓力補充。
Broken temp relay, low refrigerant; relay replacement, refrigerant pressure test & refill.
11. 加濕器不出水、濕度永遠偏低乾燥雪茄11. Humidifier no water output, low RH dry out cigars+
加濕泵阻塞、進水濾芯髒污、水位感應故障;清洗水路、更換水泵與濾芯。
Blocked humid pump, dirty inlet filter, water level sensor error; clean water circuit, replace pump & filter.
12. 商用大容量雪茄櫃冷風循環不均,左右濕度落差大12. Commercial cabinet uneven air circulation, RH gap left-right+
循環風扇出力不足、風道積塵;清洗風道、升級風扇馬達、重設氣流導板。
Weak circulation fan, dusty air duct; duct cleaning, fan motor upgrade, airflow baffle reposition.
13. 櫃門無法吸合、自動彈開,無法密封保濕13. Door fail to close tight, auto pop open lose humidity lock+
磁吸減弱、鉸鏈鬆動、膠條移位;更換門磁石、調整鉸鏈、重貼密封條。
Weak door magnet, loose hinge, shifted seal; new magnet install, hinge tune, reattach rubber strip.
14. 內層雪松木發霉變黑、釋放刺鼻木霉味14. Cedar wood shelf mold blacken, release pungent mildew smell+
長期高濕無通風;拆除木層板高溫消毒除霉,更換全新進口雪松木配件。
Long term high humidity no ventilation; remove cedar for high temp disinfection, replace new imported cedar planks.
15. 機身外殼凝露滴水,電路短路風險15. Cabinet outer shell condensation drip, risk circuit short circuit+
隔熱層老化、室內溫差過大;補充隔熱棉、校正溫度設定、加裝防凝露加熱線。
Aged insulation, big indoor temp gap; refill insulation foam, adjust temp setting, install anti-condensation heater wire.
16. 濕度感應儀數值失真,顯示與實際濕度差距超10%RH16. RH sensor reading wrong, 10%RH difference from real humidity+
感測器灰塵覆蓋、電路老化;深度清潔感測探頭,無法修復則替換原廠感應模組。
Dust covered sensor, aged circuit; deep clean probe, replace genuine sensor module if broken.
17. 開機後數分鐘自動斷電、保護燈閃爍報警17. Auto power off minutes after startup, warning light flash+
壓縮機過載、電容短路、散熱不良;檢查電路負載、更換電容、清理冷凝器灰塵。
Compressor overload, short capacitor, poor heat dissipation; circuit load test, capacitor swap, condenser dust cleaning.
18. 原廠專用活性炭濾網難購,市面替代濾網效果差18. Hard to buy genuine Vinvautz carbon filter, generic filter low efficiency+
本店備齊全型號Vinvautz原廠濾網,現貨更換,吸附效果恢復出廠標準,無需等待訂貨。
We stock full range genuine Vinvautz carbon filters, instant on-site replacement, factory standard odor absorption without lead time.
19. 長期停用後重開,櫃內累積大量黴菌異味無法清除19. Heavy mold odor after long time shutdown, hard to eliminate+
完整拆機深度消毒、風道高壓清洗、全新濾網替換、雪松木除霉護理,一次根除異味源頭。
Full disassembly deep disinfection, high pressure air duct clean, new filter & cedar mold treatment, eliminate odor root in one service.